Fire Hall Signals
Traffic Control
The Novax Fire Hall Signal Controller provides direct control of the signal lights at the fire hall and at any nearby intersections for safe, rapid deployment of fire trucks.
- Overview
- Specifications
- Ordering
- Downloads
- Highly cost-effective priority traffic access for fire vehicles
- Robust, easy to install, simple to operate, and adaptable to any fire hall location
- Single Button version for locations where the only traffic lights are in front of the fire hall
- A single press turns the lights red for both directions to stop all traffic
- A large digital display shows the number of seconds remaining before lights change
- Press the button again before the timer reaches ZERO to extend the priority time
- Dual or Triple Button versions provide signaling options suitable for fire halls located close to major street intersections that are controlled by traffic light signals
Applications:
The Novax Fire Hall Signal Control System is adaptable for use in many different fire station locations. The three scenarios shown here describe the most typical traffic control situations at fire stations and how the Novax Fire Hall Signal Control System enables safe, rapid deployment of fire trucks and other emergency vehicles.
- Operating Voltage:
- 115VAC ± 20VAC
- Operating Power:
- 5 Watts (No Output Loads Operating)
- Operating Temperature:
- -40 °C to +85 °C
- Storage Temperature:
- -40 °C to +85 °C
- Faceplate Displays:
- Five 7-Segment (Red) LED’s (c/w “Sleep Mode” -shuts Display OFF when Not in Use)
- Input Displays:
- Three (Red) LED’s (3 for Inputs)
- Output Displays:
- Six (Red) LED’s (6 for Outputs)
- Keypad:
- MODE, UP & DOWN Switches for Controller Setup
- Test Switches:
- Three Push Input Test Switches (on Panel)
- DC Inputs (External):
- Two Normally Open – (N.O.) Dry Contact Closure Optically Isolated, 24VDC, 0.2 A (Inputs 1 & 2)
- AC Inputs (External):
- One Normally Open – (N.O.) Dry Contact Closure Optically Isolated, 115VAC, 0.2 A (Input 3)
- Outputs:
- Six 115 VAC, Solid State & Zero-crossing. Rated for Tungsten Lamps. Fused @ 10 Amperes each
- Terminal Barriers:
- Accepts up to 10 AWG Wire
- Interval Timers:
- Nine User-Adjustable (0 – 250 Seconds)
- Start Delay Time
- Flashing Yellow Time
- Steady Yellow Time
- Steady / Alternating Flashing Red Time
- Extend ‘1’ Time
- Extend ‘2’ Time
- Extend ‘3’ Time
- Preemption ‘1’ Delay Time
- Preemption ‘2’ Delay Time
- Minimum Vehicle Passage Time
- Nine User-Adjustable (0 – 250 Seconds)
- Countdown Timer:
- Runs concurrently with the Interval timers
- PLS000874:
- Fire Hall Controller
- PLS000874:
- Endlosure for Fire Hall Signal Controller
- OPT001518:
- Fire Hall Pushbutton supplied by Novax
- OPT001068:
- Pre-emption Pushbutton Supplied by Novax
- OPT001070:
- One set of left and right approach signals
- OPT001071:
- Two sets of left and right approach signals
- OPT001992:
- Three sets of left and right approach signals
- FIN000410:
- Countdown Timer Module
- FIN000649:
- Green Signal Head Eclosure for Countdown timer
- FIN000665:
- Yellow Signal Head Enclosure for Countdown timer